HomeMy WebLinkAboutCity Council Resolution 1997-428•
CITY OF PLYMOUTH
RESOLUTION 97428
APPROVING SITE PLAN AMENDMENT FOR BUHLER, INC. FOR A BUILDING AND
PARKING EXPANSION AT 1100 XENIUM LANE NORTH (97090)
WHEREAS, Buhler, Inc. has requested approval of a Site Plan Amendment to allow an
expansion of the office building and parking lot at 1100 Xenium Lane North; and
WHEREAS, the Planning Commission has reviewed said request at a duly called public meeting
and recommends approval.
NOW, THEREFORE, BE IT HEREBY RESOLVED BY THE CITY COUNCIL OF THE CITY
OF PLYMOUTH, MINNESOTA, that it should and hereby does approve the request by Buhler,
Inc. for a Site Plan Amendment subject to the following conditions:
1. The Site Plan Amendment allows a 10,557 square foot addition to the office building and
97 new parking spaces south of the existing office parking lot, in accordance with the
plans received by the City on June 20, 1997, except as amended by this resolution,
2. Prior to issuance of building permits, all plan sheets must be signed.
3. Prior to issuance of building permits, the applicant shall submit a lighting plan for staff
review and approval that indicates the .5 foot-candle contour line within the lot lines.
4. Prior to issuance of building permits, the applicant shall revise the plans to indicate the
allowable area calculations for staff review and approval.
5. Prior to issuance of building permits, the applicant shall revise the plans to indicate 26 -
foot wide drive aisles and 18.5 -foot deep perking spaces.
6. Prior to issuance of building permits, the applicant shall revise the plans to indicate nine
handicap parking spaces, in locations as approved by the Building Official.
E
7. Prior to issuance of building permits, the applicant shall revise the plans to include the
required notation relating to the screening of any rooftop equipment.
8. Prior to issuance of building permits, the applicant shall revise the plans to include the
required notation stating: 'rhe diameter of piping required for domestic and lawn
irrigation water supply shall be no more than V4 the diameter of the building water
service".
9. Prior to issuance of building permits, the applicant shall revise the plans to comply wilt
the Fire Division requirements relating to spacing of fire hydrants and submittal of fire
now calculations.
lo. The existing building and proposed addition shall be sprinkled with a fire sprinkler
system
11. Prior to issuance of building permits, the applicant shall revise the plans to include the
fire lane engineering detail, fire hydrant engineering detail, fire lane signage detail,
temporary access roads and water supply policy, and Plymouth Fire Department notes.
12. Prior to issuance of building permits, the applicant shall revise the plans to indicate the
location of the Fire Department connection and post -indicator valve.
13. Prior to issuance of building permits, the applicant shall obtain the required permit from
Bassett Creek Watershed.
14. the grading, drainage, and erosion control plan shall comply with all City requirements
and the requirements of Bassett Creek Watershed.
15. Prior to issuance of building permits, the applicant shall revise the plans to indicate the
silt fence entirely on the Buhler property.
16. Prior to issuance of building permits, the applicant shall revise the plans to include details
of the flared end -section and NURP pond.
17. Prior to issuance of building permits, the applicant shall revise the plans to indicate rip-
mp swales from the parking lot to the normal water level of the NURP pond.
18. Prior to issuance of building permits, the applicant shall revise the plans to indicate ten
total new trees on the site, including species, size, and location for staff review and
approval.
19. Standard Conditions:
A. Compliance with the City Engineer's Memorandum.
C
•
Resolution 97428
MM)
Page. 3
B. Submission of the required Financial Guarantee and Site Performance Agreement for
completion of site improvements within twelve months of the date of this Resolution.
C. An 8 1R x I1 inch "As Built" Fire Protection Plan shall be submitted prior to the
release or reduction of any site improvement bonds per City Policy.
D. Any subsequent %'am or expansions are subject to required reviews and approvals
per Ordinance provisions.
E. Compliance with the Ordinance regarding the location of fin hydrants, fire lanes, fire
suppression and fire lane signage.
F. The permit is subject to all applicable codes, regulations and ordinances, and
violation thereof shall be grounds for revocation.
G. An approved lock box shall be provided on the building for Fire Department use. The
lock box should be monitored by a UL central station and located by the fire
departra&.t connection or vi located by a Fire Inspector.
H. This approval shall expire one year after the date of approval, unless the property
owner or applicant has substantially started construction of the project, or unless the
landowner or applicant has received prior approval from the City to extend the
expiration date for up to one additional year, as regulated under Section 21045.49 of
the Zoning Ordinance.
Adopted by the City Council on July 23, 1997.
STATE OF MINNESOTA)
COUNTY OF HENNEPIN) SS.
The undr:rs ped, being the duly qualified and appointed City Clerk of the City of Plymouth,
Minnesota, certifies that I compared the foregoing resolution adopted at a meeting of the
Plymouth City Council on July 23, 1997, with the original thereof on file in my office, and the
same is a correct transcription thereof.
WITNESS my hand officially as such City Clerk and the Corporate seal of the City this
day of
City Clerk
•