Loading...
HomeMy WebLinkAboutCity Council Packet 06-25-2002 SpecialAgenda City of Plymouth Special City Council Meeting Tuesday, June 25, 2002 5:30 p.m. Public Safety Training Room 1. Call to Order 2. Review concept plans for lower level of the Plymouth Creek Center 3. Discuss proposed dome for the tennis courts at Oakwood Elementary School 4. Schedule future study sessions A. City Web Redesign 5. Adj ourn Agenda Number: CITE' O 'LIOU`PS CU Q 'f ILj' t SPORT TO: Dwight Johnson, City Manager 091 FROM: Eric Blank, Director of Parks and Recreation JJ SUBJECT: Plymouth Creek Center Lower Level Improvements DATE: June 20, 2002, for Council Meeting of June 25 1. BACKGROUND INFORMATION: Earlier this year the City Council authorized the hiring of architect Del Erickson to begin preparing concepts for the finishing of the lower level of the Plymouth Creek Center. In order to move the project forward, I formed an internal design task force. Members consisted of Dwight Johnson, Mark Jones, Rick Busch, Diane Evans, Sara Mittelstaedt, Nick Tigue, Karol Greupner, Regina Michaud, and me. We put together a design program for the facility which is outlined in a memo dated May 10 from Del Erickson to me and attached for your review. Based on this design criteria, the architect started developing a series of concept plans for the lower level. After review by the design task force, we took them to the senior council and the youth council for their review and comment. The Park and Recreation Advisory Commission also reviewed this at their June meeting. The Commission had favorable comments about the design. Their one concern was about noise. We have also had some review by members of the arts council. Based on the comments of these different groups, we went back to the drawing boards and made changes to the plan to reflect the comments of both the seniors and the youth. The staff task force is now comfortable that the plan is a very good layout meeting most of the needs that we had set out to address. A copy of the plan and 3D renderings are attached for your review. Del Erickson will be at the 5:30 study session to further explain the concept to the Council. A preliminary project budget is also attached. If the Council is in agreement with this basic concept, we need to move forward with further refinement of the plan and some more detailed cost estimating. At this time, we estimate we have an approved budget for approximately one third of the space in the facility. We will, however, per Council direction, look to see if there are other funding sources available for completing more of the project. A schedule for the project, which is quite aggressive, is also laid out in the May 10 memo from Del Erickson. MEMORANDUM /PROGRAM DATE: May 10, 2002 TO: Eric Blank, Design Task Force FROM: Del Erickson RE: Plymouth Creek Center Lower Level Finishing Commission No. 0213 The following program and approach for the design is based on a meeting with Eric Blank and Del Erickson on May 7, 2002. The design will address the various needs of the City's seniors and youth by finishing a portion or all of the lower level of the Center. A cost estimate and functional analysis will be developed for each of the concepts. Initially, a master plan comprising all of the lower level will be prepared, showing potential phasing and budget alternatives. Design Task Force Dwight Johnson Eric Blank Mark Jones Rick Bush Diane Evans Sarah Mittlestadt Nick Tig Carol Greupner Review Groups Senior Group Youth Council Floor plans will be developed with alternative concept designs and cost estimates, along with impact on budget. The basic program space requirements are as follows: Lower Level Space Program 1. Concession Area Serving counter - two lanes Menu to be determined: Serve malts? Ice cream? Grill and microwave? Provide storage for products. Three -compartment sink. Disposable service ware. Sit-up counter for 4 to 6 people. T'd B82.ON SGNOM N3H10 NI 300 s.f. wdTT : TT 2222'2T *,,Hw Eric Blank, Design Task Force May 10, 2002 Page 2 2. Dining Lounge 1,300 s.f. 10 to 15 round tables. Vending machines. Direct access to fieldhouse lounge, exterior and Iobby with view from counter. Connection to Card/Multi-Use Room. 4 computer carrels. 3. Card/Multi-Use Room 1,300 s.f. 10 to 15 square tables. Storage closet/cabinet. Operable wall to expand. 4. Conference Room 400 s.f. Table and chairs for 12 to 16 people. Storage cabinet and video. View to exterior. 5. Music Practice Room 200 s.f. 2 prefab soundproof rooms. G. Storage 1,000 s.f. Building and equipment storage. Office and work bench area. 7. Tiered Multi -Use Space 2,000 s.f. 8"+ tiers for performing view. Stage/demonstration area accessible by ramp. Nightclub atmosphere. Accommodate 100+ people. Total Net Area: 6,500 s.f. Net to Gross Conversion: +10% Total Program Gross Building Area: 7,350 s.f. Total Potential Gross Program Area, Based on Existing: 7,200 s.f. Design Considerations Visual connection to upper level and control from central office. Service access from existing and exterior. Flexibility and expandability of each function. Relation to garden. Maintenance and durability. Joint use of existing toilets, Fieldhouse, lounge, concessions and lobby. View of activities from public area. Aesthetics of design to fit existing and be appealing to young. The Master Plan concepts will be developed for a review in mid-May. z'd es2*ow SQNOM N3H10 NI Wdtt:tt 2002'0Z'AbW Eric Blank, Design Task Force May 10, 2002 Page 3 Overall Schedule Start Program Review Design Options Review Final Schematic Design Senior and Teen Group Review Design Development Review by Park Commission Counsel Approval Working Drawings Advertise for Bids Bids Due Council Approval of Contractor Start Construction Substantial Completion Final Acceptance DEA/tlt May 7, 2002 May 14, 2002 May 21, 2002 May 31, 2,002 Week of June 3, 2002 June 13, 2002 June 25, 2002 July 1, 2002 through August 8, 2002 August 8, 2002 August 29, 2002 September 9, 2002 October 1, 2002 December 15, 2002 January 15, 2003 E'd 882"0H SGNOM N3H10 HI WHTT:TT 2002'0T'J'Hw 06/21/2002 11:36 6125455433 ERICKSON PAGE 01 MENTORANDiuM / PROGRAM DATE: June 20, 2002 TO. Etic Bleak FROM: Del Erickson RE, PCC Lower Level Finishing S. Steel Corrmission No. 02'.; The following information is an update to our previous memo of May 10, 2002 and cost estimate fet the above project_ The design task force added Regina Michaud. Master Plan schemes A through D have been developed and reviewed with the task force and teen and senior groups. Scheme A had a rough cost estimate of $610,000. Purther refinements and incorporation of group input and more control (sound and access) with mainta.ining flexibility have resulted in Scheme E. Scheme E has the following cost estimate. 1. General Conditions 104,000 2. Demolition/Site 20,000 3. Concrete 33,000 4. Masonry 8,000 S. Steel 14,000 6. Carpentry 69,000 7. Weather/Sound 15,000 S. Doors and Windows 104,000 9. Finishes, 110,000 10. Specialties 22,000 Total General Construction. S499,000 15, Mechanical 66.000 16. Electrical 59.000 Total, Construction Cost Estimate: 624,000 Contingmcv - 10% 62,500 A/E Sco-ices - 9%. ANO Total Budget - 7200 s.f. 0 103.20 S743,000 This number is close to the original $100/s .f. which we had initially discussed. Phasing of project to fit the proposed budget of S225,000 will accommodate roughly one-third of the project with selective use of finishes and operable partitions DE/tlt T I-1 77TG'OKI r -a.4 iM A-4WIf'- \IT WH);1!n1 PIR t?'Ijnr 10 v KIN C' El r -n C'1 O O y OAM, O O C fa` P o , J,000 0000 700joo laooS<oo000 I G- _ 00 G045 d ED M. U. 4OO- 0TERED A oJJJo h MAINiE 'G= 1'b'SLO GiN'IMf 51C i~ -- OEfICE O , GENE RA- jL Sid R'G= -BOO STORAGE '7 L -ll iLLlil 3F, u IIG D I I I i 0i m LOWER LEVET_ FLOOR PLAN r J AFI m I if 1 l [ ', i I 1111 ,. = I, PERSPECTIVE e a PEI ,PELT.= I I I I I Agenda Number: :3 TO: Dwight Johnson, City Manager FROM: Eric Blank, Director of Parks and Recreation SUBJECT: Oakwood Tennis Courts/Indoor Tennis Dome DATE: June 20, 2002, for Council Meeting of June 25 1. BACKGROUND: Earlier this year the City Council authorized the reconstruction of the tennis courts at Oakwood Playfield. There are currently five tennis courts at Oakwood. At this time we are proposing to replace them with four tennis courts and one outdoor basketball court. The budget for this project is $140,000 with the funding coming from the Park Replacement Fund. For the last two years I have been getting calls and letters regarding an indoor tennis facility in the City of Plymouth. Many people are wondering if they can play indoor tennis at the Plymouth Creek Center Fieldhouse. We have a large seniors' tennis group that plays two or three times a week during the summer months at the Parkers Lake courts. This group has also been inquiring about the availability of indoor tennis, because they have to travel such great distances to play at other locations. With this in mind we began planning replacing the tennis courts at Oakwood, we decided to contact the Yeadon dome manufacturer to actually find out what the cost would be for doming four tennis courts. I was pleasantly surprised to learn that the basic cost was $194,500 for a dome structure. Because this is so reasonable I began to explore the subject a little further. I set up meetings with representatives of the seniors' tennis group, with coaches at Wayzata High School, and I met with my staff responsible for our city tennis program. What I have discovered is that while there is a slight decline in the interest of tennis nationally, the interest in Minnesota appears to be holding steady, and more specifically in Plymouth, the tennis program at the community level, at the senior level, and at the high school level is very strong and vibrant. I next set up a meeting with representatives of the Wayzata School District to review the proposal of installing a tennis dome at the Oakwood courts. During the course of this meeting, the school district staff inquired as to the availability of the school district using the tennis bubble for their tennis program. They specifically indicated that they would consider a program similar to what we have at the Ice Center where they become a renter of the facility on a lease basis. I indicated to them that I would further explore this subject and send them a letter outlining what the proposed cost might be in order to make the project viable. Attached for Council review is a series of documents pertinent to this subject: estimated construction cost, estimated annual operating cost for the facility, estimated income for the facility, memo from Mike Kohn outlining the estimated cost for gas and electricity, memo from Yeadon outlining the cost of the bubble structure, annual payment schedule for a potential lease between the City and the school district, fair market value of the school district using 2,080 hours of bubble time at $20 an hour. We think Oakwood is a viable site for a number of reasons. First the courts are currently going under reconstruction and it would be easy to add the necessary underground utility work at this time. Second, it's located at a major intersection of County Roads 101 and 6. Third, the entire site is surrounded by a 30 feet or more of solid evergreen trees, and fourth, the Wayzata School District finds this a viable site for entering into a lease agreement with the City. The attached aerial photo shows the layout of the three soccer fields, the softball field, and the current tennis courts at Oakwood. The courts are strategically placed to be approximately 400 feet or more from residential homes. For comparison purposes the existing fieldhouse dome at the Plymouth Creek Center stands 65 feet tall and covers a floor space of approximately 68,250 square feet. The tennis court bubble would stand 36 feet high and cover 24,072 square feet. Thus, it's about 35% of the square footage size of the current fieldhouse. Currently our architect is drawing up the plans and specifications for the new tennis courts at Oakwood. We have included an add alternate bid for excavation and placement of the concrete grade beam around the perimeter of the courts. If we think that this is a project that might be viable this year or within the next three years, it would be in the best interest of the City to go ahead and install the structural grade beam (est. cost $65,000) at this time. That decision would not have to be made until we award a contract for the new courts. If the Council thinks this is a viable project that should be explored further, there are some steps the staff would recommend. First we need to give a written proposal to the Wayzata School District to see if: a) they will agree to the facility being placed at the Oakwood site as per our lease agreement on the property, and b) whether or not they wish to formally enter into a lease agreement for the use of the tennis center with the City of Plymouth. The facility would also require a conditional use permit. To this end, we should have some form of communication with area residents informing them of the possibility of the tennis bubble and getting their feedback as early as possible. Finally, the funding for this project is proposed to come from the park replacement fund. This fund currently has a balance in excess of $4 million. A loan would be made for the construction, which would be repaid from revenues from the rental of the tennis courts and the lease agreement from the school district at an interest rate currently estimated to be 6.42%. EB/np Oakwood Tennis Dome 0 Construction Costs Dome 1945500 Concrete Grade Beam 655P000 Wiring between ballast 5,000 Electrical design 3,500 Electrical Supplies 27,000 Gas Connection 7,500 Phone 750 Drinking Fountain 35P000 Sales tax 55P000 City Permits 1,000 Wind sensor 8,000 First installation 25P000 H.C. entrance 9,500 Fence upgrade 20,000 351,750 10% Contingency 35,175 Total $386,925 Oakwood Tennis Dome Estimated Operating Expenses 5TAP 45 prime time hours x 26 weeks = 1,170 hours 1,170 hours x $10/hour = $11,700 or 1,170 hours x $11 /hour = $12,870 Natural gas (range) $9,000 — $19,800 Electricity Base Cost Set Up/Take Down Insurance Miscellaneous Total est. $14,500 12,600 39,970 4,000 5,000 3,000 51,970 rol Hours Open Mondays 5:30-10:30 Tuesdays 5:30-10:30 Wednesdays 5:30-10:30 Fridays 5:30-10:30 Saturdays 9:00-9:00 Sundays 1:00-9:00 Oakwood Tennis Dome Estimated Income Prime Time Hours 5 5 5 5 12 8 45 X 4 courts Income if Fully Sold 180 hours of prime time per week Hours Per Week Hourly Rate Income Per Week Income for 26 weeks 180 $18 3,240 84,240 180 $20 3,600 93,600 180 $22 3,960 102,960 Income if Partially Sold Hourly Rate Total If Fully Sold Total if 50% Sold Total if 60% Sold Total if 70% Sold Total if 80% Sold 18 84,240 42,120 50,544 58,968 67,392 20 93,600 46,800 56,160 65,520 74,880 22 1 $102,960 1 51,480 61,776 72,072 82,368 11 Eric Blank From: Mike Kohn Sent: Monday, December 10, 20014:03 PM To: Eric Blank Subject: Gas & Electric Costs Golf Dome Our current cost per therm for gas is about $.50. This compares to a high of about $1.10 in January of this year. Given the consumption numbers that you gave me (18,000 therms), I would expect gas to cost between $9,000 and $19,800 per year. Electricity currently runs about $.065 per KWH. This is difficult to determine with any precision becasue electricity has a separate demand charge. Given the consumption number that you gave me (193,500 KWH), I would expect electricity tocostabout $12,600 per year. YEADONI. December 4, 2001 Plymouth Parks & Recreation Mr. Eric Blank 3400 Plymouth Blvd. Plymouth, MN 55447 RE: Pricing for a 4 court tennis dome. Dear Mr. Blank: YEADONO Fabric Domes Inc. 2845 North Hamline Ave., Suite 100 St. Paul, MN 55113 Toll Free: 800-4-YEADON Telephone: 651-633-7400 Fax: 651-633-2019 We are pleased to present the following quotation for a Yeadon Air Supported Structure. The following items are included in our proposal. Also shown are optional components and fabric finishes for your consideration. SIZE: The approximate size of the dome is 204'long X 118'wide X 36' high with a total floor space of 24,072 square feet. OUTER MEMBRANE: The outer membrane is manufactured in, 28-oz./sq. yd., white, high tensile strength, translucent, TS 116/117 acrylic topcoat, vinyl coated polyester. The fabric is fire resistant, meeting the requirements of UBC (31 -1) and NFPA 701. THERMAL/ACOUSTICAL INNER MEMBRANE: The dome contains an inner thermal/acoustical fabric liner, which is welded to the domes outer membrane. The liner is produced from an acrylic coated, white and blue, 14 oz./sq. yd., high strength, translucent vinyl coated polyester. The blue is used as a contrasting color along the sides and partially across each end. It extends from ground level to 15'. Yeadon recommends the blue over other background colors because of its superior reflective characteristics. White is used throughout the rest of the dome to provide the brightest interior possible. This highly durable liner provides maximum protection against abrasions and tears that can occur during seasonal installations and takedowns. SEAMS: All seams are dielectrically welded together to form the domes profile. This method of fabrication provides an airtight bond that is stronger than the material itself. Yeadon uses no sewn seams on its structures. SECTIONS: The dome will be manufactured in 2 sections for ease of handling. If more than one section is required, Yeadon will provide 8" aluminum seam clamps, which are used to field connect the sections together. These seam clamps form a strong, airtight and flexible connection. A continuous fabric flap with a VELCRO edge is also provided to conceal and weatherize the seam connection. In Canada Kerr Industrial Park, R.R. #3 Guelph. Ontario, Canada NIH 61-19 Telephone: 519-821-9301 Fax: 519-821-9010 ALUMINUM CHANNEL: 640' of Yeadon's exclusive anodized aluminum channel will b_e,rovided for installation into t e-concrete_grade beam by your concrete contractor. This unique anchoring system was developed by Yeadon to provide the most energy efficient, economical and easy to install method of anchoring the dome. The channel system provides for even distribution of uplift loads and forms an airtight bond around the entire perimeter base of the dome. It reduces annual energy costs, seasonal installation and take down costs, storage space and also, it leaves no protrusion or tripping points during the off season when the dome is down. CABLES: Cables are not required on many Yeadon air structures. This advanced engineering design eliminates the inherent problems created by cables such as snow entrapment, membrane marring and the extra expense of the cables, seasonal installation and take down costs and storage. REVOLVING DOOR: An aluminum, 4 -leaf revolving door is supplied for the main entrance into the dome. This self-contained door comes complete with full glass paneled doors, rigid frame and sides, sturdy tread -plate base and all attaching hardware. EMERGENCY EXIT DOORS: 4 balanced aluminum emergency exit doors complete with a heavy duty steel frame, viewing panel, panic hardware, exit lights with battery backup, lockable exterior entry hardware, fabric clamping strip, exterior knee braces and all attaching hardware. 1- 40" clearspan door is included for handicap accessibility. LIGHTS: _ - 1000 watt metal halide fixtures, lamps, double ballast assemblies, swing base poles, crossarms, factory wiring to pole base and attaching hardware. 40 - Suspended 1000 watt metal halide fixtures, lamps, ballast, hangers, chain, and attaching hardware. Wiring between ballast and fixture issupplier_ d others. Others provide all electrical design, distribution and wiring to the le or light locations. Yeadon will assist with the layout and location of the lights and/or poles. FURNACE/INFLATION/STANDBY: This sophisticated " ALL IN ONE " inflation package comes complete with a 2.0 MBTU indirect fired furnace with a full modulating burner, stainless steel heat exchanger, thermostatic temperature control and all state of the art operating components. The inflation package consists of a high efficiency electric motor, fans, motorized dampers for pressure control and a remote control station that allows you to vary the domes internal pressure from a remote location. The remote control station also gives you burner on/off control, indicator lights for the fan, standby and burner, a pressure gauge showing the domes internal pressure and a potentiometer that allows you to adjust the domes internal pressure to its most energy efficient level as dictated by wind conditions. 2. The built-in standby inflation system consists of 1 electric motor, 1 natural gas driven engine, a separate inflation fan, a photohelic pressure gauge, all state of the art operating components, a battery and a charger. The standby system will detect low-pressure situations or power outages and automatically start the appropriate fan and motor system. The standby will deliver air into the dome through the return air duct, thus eliminating a third ducting system required with separate standby systems. The above components are contained within a weatherized steel housing that is insulated for sound. There are access doors and panels conveniently located around the unit. This complete inflation package gives you the most energy efficient and cost effective method of inflating and heating the dome. To further enhance its efficiency, please see the options section under Wind Sensor. There is only one electrical and one gas connection . required to get the system up and running. Yeaon will provide the initial start up of the complete system once it arrives on site. Whenever possible, Yeadon recommends our unique bottom discharge air delivery system. This system uses underground ducts for the supply and return air. This allows you to move the inflation system away from the dome to facilitate snow removal and it improves heat distribution throughout the dome. If the bottom discharge system will not fit your site, we have end and side discharge systems available as well for a slightly extra cost. DRAWINGS: Yeadon will provide construction drawings, calculations and specifications of the dome for permit application. These drawings require local engineering stamps. FREIGHT: F. O. B. Factory. PRICING: Our price for all the above components is $ 194,500.00. TERMS: 30% deposit due with order and signed contract, 40% due upon completion of manufacturing, 25% due upon delivery and 5% holdback due 30 days after installation. This proposal is good for a period of 60 days. ITEMS NOT INCLUDED: The following items are not included in this proposal. 1) Any costs of Federal, State or Local taxes. 2) Any costs of permits, energy analysis, local engineering stamps, electrical or mechanical engineered drawings that may be required by local authorities. 3) Any costs of installation, construction, supervision, site preparation, site access, unloading freight, site or fence modification and/or restoration, on-site construction visits, bringing utilities to the site and any electrical or gas distribution and hook up. 3. OPTIONAL ITEMS: The following can be added to this proposal. SUPERVISION: A Yeadon supervisor is required for the installation of the dome. This representative is available for $ 500.00 per 10 hour day plus travel and living expenses. TEDLAR: A TEDLAR coating can be applied to the outer membrane for $ 19,000.00. The coating will provide maximum membrane protection from pollution, dirt and UV rays. OPAQUE: An opaque outer membrane can be added for $ 5,000.00. WIND SENSOR: A wind sensor can be provided to automatically adjust the domes internal pressure to its most energy efficient level as dictated by outside wind conditions. This device can come with an optional sensor to detect low-pressure situations and be programmed to notify someone that attention is required. It also has a nighttime temperature setback option and wind direction indicator option. The wind sensor can pay for itself in energy savings within 2 years of operation. Price starts at $ 6,500.00. Tower mounting, wiring and installation are not included. HANDICAP ACCESSIBLE ENTRANCE MODULE: An entrance module complete with 2 balanced aluminum doors, rigid frame with aluminum wall and roof panels that attaches directly to the revolving door can be added for $ 9,500.00. DIVIDER NETS: These can be supplied to divide courts. Add $ 900.00 per divider net. If you need further information on this proposal, please contact me at 800- 4YEADON. Thank you again for this opportunity to propose this dome to you and I hope to hear from you soon. Sincerely, Steve Fl pagan President Yeadon Fabric Domes, Inc. El Wwagidy Payment Schedule Tennis Court Improvements 150,000 Principal 15 Payments 6.42% Interest Rate 15,871.03 193,462 Principal 15 Payments 6.42% Interest Rate 20,469.61 200,000 Principal 15 Payments 6.42% Interest Rate 21,161.37 232,155 Principal 15 Payments 6.42% Interest Rate 24,563.59 250,000 Principal 15 Payments 6.42% Interest Rate 26,451.72 270,847 Principal 15 Payments 6.42% Interest Rate 28,657.47 Tennis Court Improvement Payment Schedules.xls 6/19/2002 666 School District Use by Hour 4 hours x 4 courts = 16 hours/day 16 x 5 = 80 hours/week 80 x 26 = 2,080 hours/season 2,080 x $20 = $41,600 (market value of court time) Facility Construction Cost 386,925 x 50%= $193,4621 0 15 years x 60%= $232,1551 x 70% _ $270,8471 See attached payment schedule. Page 1 of 1 Eric Blank From: Edward Fischer [cfisc2348@worldnet.att.net] Sent: Wednesday, June 19, 2002 9:12 PM To: eblank@ci.plymouth.mn.us Subject: Tennis court charges Dear Eric, In response to your question about charges for indoor tennis time, $18-22 per hour for court time is consistent with fees charged by Williston Sports Center in Minnetonka and various Northwest Racquet club facilities in the metro area. Ed Fischer 763-550-9770 6/21/2002 filc:H1~:\D('I-'i'.vt'\1.47CANON'A.L.IT-4701.3PG 6/19/2002 Fage I ot I filel[FAI)CM147CANONAUIT 4702-JPG 61/19/2002 Page I of I il ttCh,t-k 7D (OAkLAAV file:/,,'F-I\I)CI.MN-147CAiNIONr\.&UT 4703JOP6 6/19/2002 Pave I of I 014 7'b c-,(), eo (,o file //F A)CI NM\ 147C ANON" AUT 4704. JPG 6/19/2002 page, 1 Of I A(0kb Al-il - 71> AWIF 6/19/2002file://FADClMlJ 47CANON\At , r r-.,.,4705.JPG- Page I ot'l hct-ltt, 19/2002 file: //F:\DCIM\l 47CANON\At.JT--4706,jpci (i, Page I of ) file.,,"/I.,\DCIM147CA NON\At.)'I' 4707JPG 6/19/-'1"00'2 Avg- Ar. g ti 04 L y n Agenda Number - TO: Dwight D. Johnson, City Manager FROM: Laurie Ahrens, Assistant City Manager AV SUBJECT: Set Future Study Sessions DATE: June 20, 2002, for Council study session of June 25, 2002 I. ACTION REQUESTED: Review the pending study session topics list and establish future special meetings if desired. II. DISCUSSION: The pending study session topics list is attached, along with calendars to assist in scheduling. The Council previously indicated it would consider establishing a study session date on the City Web Redesign at this meeting. This project is underway, and the Council has already reviewed the site objectives and graphic design elements. The Information Technology and Communications staff is currently working with each division to ensure that their needs are incorporated into the redesigned site. We request that the Council schedule a study session during the week of July 15 or 22 to preview the site and provide feedback on the ease of use and site navigation. The new site is slated to be launched by the end of summer. Pending Study Session Topics at least 3 Council members have approved the following study items on the list) I-494 Corridor Commission (Slavik, Black, Hewitt) OFFICIAL CITY MEETINGS July 2002 Sunday Monday Tuesday Wednesday Thursday Friday Saturday 1 2 3 4 5 6 5:15 PM MUSIC INDEPENDENCE IN PLYMOUTH, DAY - City City Center Offices Closed Amphitheater 7 8 9 10 11 12 13 7:00 PM 7:00 PM PARK & REGULAR RECREATION COUNCIL ADVISORY MEETING, Council COMMISSION Chambers PRAC) SPECIAL MEETING, Plymouth Creek Center 14 15 16 17 18 19 20 7:00 PM 7:00 PM HRA - PLANNING Medicine Lake Room COMMISSION, Council Chambers 7:00 PM PUBLIC SAFETY ADVISORY BOARD, Polies DePL Library 21 22 23 24 25 26 27 7:30 AM LOCAL BUSINESS 7:00 PM PACT - Bass Lake Room COUNCIL, Radisson Hotel 7:00 PM REGULAR COUNCIL MEETING, Council Chambers 28 29 30 31 Jun 2002 Aug 2002 S M T W T F S S M T W T F S 1 1 2 3 2 3 4 5 6 7 8 4 5 6 7 8 9 10 9 10 11 12 13 14 15 11 12 13 14 15 16 17 16 17 18 19 20 21 22 18 19 20 21 22 23 24 23 24 25 26 27 28 29 25 26 27 28 29 30 31 30 modified on 6/21/2002 OFFICIAL CITY MEETINGS August 2002 Sunday Monday Tuesday I Wednesday Thursday Friday Saturday 1 2 3 Ju12002 Sep 2002 S M T W T F S S M T W T F S 1 2 3 4 5 6 1 2 3 4 5 6 7 7 8 9 10 11 12 13 8 9 10 11 12 13 14 14 15 16 17 18 19 20 15 16 17 18 19 20 21 21 22 23 24 25 26 27 22 23 24 25 26 27 28 28 29 30 31 29 30 4 5 6 7 8 9 10 7:30 PM YOUTH 5:30 PM NATIONAL NIGHT 4:00 PM ANNUAL PARK TOUR, ADVISORY OUT depart from City COUNCIL, Hall Council Chambers 7:00 PM PLANNING COMMISSION, Council Chambers 11 12 13 14 15 16 17 7:00 PM REGULAR 7:00 PM EQC, Bass Lake Room 7:00PM HRA - Medicine Lake Room COUNCIL MEETING, Council Chambers 7:00 PM PUBLIC SAFETY ADVISORY BOARD, Police Dept. Library 18 19 20 21 22 23 24 7:30 PM YOUTH 7:00 PM PLANNING ADVISORY COMMISSION, COUNCIL, Council Chambers Council Chambers 25 26 27 28 29 30 31 7:00 PM SPECIAL 7:30 AM LOCAL BUSINESS 7:00 PM PACT - Bass Lake Room COUNCIL COUNCIL, Radisson MEETING: Hotel BUDGET STUDY SESSION, Public 7:00 PM REGULAR Safety Training COUNCIL MEETING, Coundl Chambers Room modified on 6/21/2002 OFFICIAL CITY MEETINGS September 2002 Sunday Monday Tuesday Wednesday Thursday Friday Saturday 1 2 3 4 5 6 7 LABOR DAY - City Offices Closed 7:00 PM SPECIAL 7:00 PM PLANNING 7:00 PM HUMAN RIGHTS COMMISSION Council Chambers Rosh Hashanah begins at sunset COUNCIL COMMISSION, MEETING: Council Chambers BUDGET STUDY 7:00 PM SPECIAL SESSION, Public COUNCIL MEETING: BUDGETSTUDY Safe TrainingSafetyg SESSION, Public Safety Room Training Room 8 9 10 11 12 13 14 7:00 PM REGULAR PRIMARY ELECTION DAY 7:00 PM EQC, Bass Lake Room 7:00 PM PRAC, Council Chambers 10:00 AM -5:00 PM AUTUMN COUNCIL Polls are open ARTS FAIR, MEETING, Council Parkers Lake Chambers 7 AM - 8 PM Patio 15 16 17 18 19 20 21 Yom Kippur begins at sunset 7:30 PM YOUTH 7:00 PM PLANNING 9:00 AM - 3:30 PM 7:00 PM HRA- Medicine Lake Room ADVISORY COMMISSION,700 pM PUBLIC PLYMOUTH COUNCIL, Council Chambers SAFETY ADVISORY BOARD, CLEAN-UP Council brary Dept. DAY, Public Chambers Works Maintenance Facility 22 23 24 25 26 27 28 7:30 AM LOCAL BUSINESS 700 PM PACT - Bass Lake Room COUNCIL, Radisson Hotel 7:00 PM REGULAR COUNCIL MEETING, Council Chambers 29 30 Aug 2002 Oct 2002 7:30 PM S M T W T F S S M T W T F S YOUTH 1 2 3 1 2 3 4 5 ADVISORY COUNCIL, 4 5 6 7 8 9 10 6 7 8 9 10 11 12 Council 11 12 13 14 15 16 17 13 14 15 16 17 18 19 Chambers 18 19 20 21 22 23 24 20 21 22 23 24 25 26 25 26 27 28 29 30 31 27 28 29 30 31 modified on 6/21/2002