HomeMy WebLinkAboutCity Council Resolution 2008-262CITY OF PLYMOUTH
RESOLUTION 2008-262
APPROVING A SITE PLAN AMENDMENT TO ALLOW A BUILDING ADDITION AND
PARKING EXPANSION FOR ZERO -MAX FOR PROPERTY LOCATED AT 13200 6th
AVENUE NORTH (2008061)
WHEREAS, Kraus -Anderson Constriction Company has requested approval of a site plan
amendment for the constriction of a 21,000 -square foot building addition and a 49 -stall parking
expansion for Zero -Max, for property legally described as:
Lot 2, Block 1, Carlson Companies 4t1' Addition, Hennepin County, Minnesota.
WHEREAS, the Planning Commission has reviewed said request at a duly called public meeting
and recommends approval.
NOW, THEREFORE, BE IT HEREBY RESOLVED BY THE CITY COUNCIL OF THE CITY
OF PLYMOUTH, MINNESOTA, that it should and hereby does approve the request by Kraus -
Anderson Constriction Company for a site plan amendment, subject to the following conditions:
A site plan amendment is approved to allow the constriction of a 21,000 -square foot building
addition and a 49 -stall parking expansion, in accordance with the application materials
received by the City on July 10, 2008, and revised plans received on August 5, 2008 and
August 11, 2008, except as amended by this resolution.
2. A grading permit is required prior to any surface area modifications or grading on the
site. Approval of the site grading plan may also be approved with a building permit issuance.
3. Separate building permits, including but not limited to, sewer, water, retaining wall,
and tank permits are required prior to commencement of the project. Any retaining wall
exceeding four feet shall be engineered and shall have a minimum three-foot high fence on top
of the wall.
Resolution 2008-262
File No. 2008061
Page 2
4. Prior to issuance of any building permits, the applicant shall:
a. Complete a site improvement performance agreement and submit a financial guarantee
pursuant to Section 21045.10 of the Zoning Ordinance.
b. Submit a revised lighting plan in compliance with the shielding and power allowance
requirements of Section 21105.06 of the Zoning Ordinance.
c. Provide a maintenance agreement for the rain garden and sump manhole.
d. Provide a parking lot sweeping agreement.
e. Obtain all appropriate permits from the Bassett Creek Watershed District and NPDES.
f. Provide top and bottom elevations for the retaining wall. Show the location of the
concrete trick wash out location on the plans.
g. Identify reinforced concrete pipe from catch basin manhole one to the flared end section in
the rain garden. Note that the trash guard on the 15 -inch pipe is not allowed. Replace the
casting on catch basin three with R-1642 B.
h. Hydrant valves are required for all hydrants.
i. Identify B612 concrete curb and gutter for the parking lot.
j. A wetland delineation has been submitted for the site. Plan modifications may be necessary
pending outcome of the wetland field investigation.
k. Provide drainage calculations to demonstrate existing and proposed surface water runoff
for the two, ten, and 100 -year rain events. Submit drainage area maps for both existing
and proposed conditions.
1. Provide the total amount of new impervious surface area in square feet. If the new
impervious surface area is equal to or greater than one acre then a pond is required to be
constricted to meet N [_]RP standards.
m. Identify a paved access to the public way from all building exists. This can be provided
with a paved path or sidewalk to a parking lot, public sidewalk or street.
n. Relocate the northeast and northwest hydrants to approved locations.
o. The site hydrant water main must be looped.
p. Submit fire flow calculations flowing the two remote highest elevation hydrants
simultaneously. Each hydrant must flow at a minimum of 1,500-gpm at 20 -psi residual
pressure.
q. Fire lane signs are required in approved locations that the fire inspector will identify on the
site plan.
r. The nitrogen tank installation must be in compliance with the CGA P-18 requirements and
the 2007 State Fire Code requirements, which include locating the tank a minimum of 10
feet from any building openings.
5. Silt fence shall be installed prior to any constriction on the site.
6. All rooftop equipment shall be screened or painted to match the building.
Resolution 2008-262
File No. 2008061
Page 3
7. Standard Conditions:
a. The applicant shall remove any diseased or hazardous trees.
b. New signage shall receive sign permits when required and shall comply with the Section
21155 of the Zoning Ordinance.
c. Any subsequent phases or expansions are subject to required reviews and approvals per
Ordinance provisions.
d. This approval shall expire one year after the date of approval, unless the property owner
or applicant has substantially started constriction of the project, or unless the landowner
or applicant has received prior approval from the City to extend the expiration date for up
to one additional year, as regulated under Sections 21045.09 of the Zoning Ordinance.
ADOPTED by the City Council on September 9, 2008.
STATE OF MINNESOTA)
COUNTY OF HENNEPIN) SS.
The undersigned, being the duly qualified and appointed City Clerk of the City of Plymouth,
Minnesota, certifies that I compared the foregoing resolution adopted at a meeting of the
Plymouth City Council on September 9, 2008 with the original thereof on file in my office, and
the same is a correct transcription thereof.
WITNESS my hand officially as such City Clerk and the Corporate seal of the City this
day of
City Clerk